blog image

Rotary Gas Volume Convert

Main Specifications

Gas volume accuracy at base conditions
                             0,05·Q max ≤ Q ≤ Q max, ± 2,25 % absolute error;
                             Q min ≤ Q < 0,05·Q max, ± 1,25 % absolute error;

Temperature scales range: -30 to +50 ºC (with a ± 0,4 °С absolute error)

Meaturement gas absolute pressure of reduced error ± 0,1%(for K.V.R. only) up to a 0.2 / 0.5 / 0.7 / 1.3 MPa

Gas compressibility factor: NX19 mod. or GERG 91 mod

Archives: temporary, daily, monthly, emergency situations, interventions, corrector work interference, prompt

  Battery lifetime: 8 years

Three-level data protection

Remote input of gas parameters

 Ambient temperature from -25 to +55 ºC

Explosion-proof shell

 IP65 Protection Class

Supports the standard ModBus protocol

 

Advantages

Calculation of natural gas volume consumption and other non-aggressive gases and bringing them to standard conditions in accordance with GOST 2939-63.

Key Features

  • Rotary gas meter with pTZ correction (correction for temperature, pressure and compressibility factor)
  • Rotary gas meter with TZ correction (correction by temperature and compressibility factor)

Major Benefits

  • Consist of rotary meter and gas volume connection, which significantly increases the security of the accounting node.
  • Lets you instantly determine the state of motion of the medium in the pipeline.
  • Provides dynamic accuracy when operating in pulse mode.
  • Removes unregulated costs of gas volumes below Qmin. Demanding for the presence of straight sections before and after the complex.
  • Extended range of measured volumetric flow.
  • Autonomous power supply.
  • Meets the requirements of the technical regulations of equipment and protective systems intended for use in potentially explosive atmospheres, approved by the Resolution of the Cabinet of Ministers of 28.12.16 № 1055 (Module B (type examination) and module E) (conformity to type based on product quality assurance) 2G Ex ib IIA T4 Gb

Type Suits

Dimensions Type

 

Nominal Diameter, DN

 

 

Fulfillment

 

 

01 02

Maximum flow rate,    Qmax, m3 / h

Minimum volume flow rate, Qmin at volume ratio, Qmax / Qmin, m3 /year

1:100 1:160 1:250

Pressure loss Δp, Pa, not more 

G16

40

+ +
25
0.25 0.16
200
G25
+ +
40
0.40 0.25 0.16
220
G40
+ +
65
0.65 0.40 0.25
400
G65 50
+  –
100
1.00 0.65
600
G65 80
+  –
100
1.00 0.65
250
G100
+  –
160
1.60 1.00 0.65
480
G160
+  –
 250
2.50 1.60 1.00
700
G250
+  –
400
4.00 2.50 1.60
900